1.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38666444

RESUMO

Stereotactic arrhythmia radioablation (STAR) is a treatment option for recurrent ventricular tachycardia/fibrillation (VT/VF) in patients with structural heart disease (SHD). The current and future role of STAR as viewed by cardiologists is unknown. The study aimed to assess the current role, barriers to application, and expected future role of STAR. An online survey consisting of 20 questions on baseline demographics, awareness/access, current use, and the future role of STAR was conducted. A total of 129 international participants completed the survey [mean age 43 ± 11 years, 25 (16.4%) female]. Ninety-one (59.9%) participants were electrophysiologists. Nine participants (7%) were unaware of STAR as a therapeutic option. Sixty-four (49.6%) had access to STAR, while 62 (48.1%) had treated/referred a patient for treatment. Common primary indications for STAR were recurrent VT/VF in SHD (45%), recurrent VT/VF without SHD (7.8%), or premature ventricular contraction (3.9%). Reported main advantages of STAR were efficacy in the treatment of arrhythmias not amenable to conventional treatment (49%) and non-invasive treatment approach with overall low expected acute and short-term procedural risk (23%). Most respondents have foreseen a future clinical role of STAR in the treatment of VT/VF with or without underlying SHD (72% and 75%, respectively), although only a minority expected a first-line indication for it (7% and 5%, respectively). Stereotactic arrhythmia radioablation as a novel treatment option of recurrent VT appears to gain acceptance within the cardiology community. Further trials are critical to further define efficacy, patient populations, as well as the appropriate clinical use for the treatment of VT.


Assuntos
Radiocirurgia , Taquicardia Ventricular , Fibrilação Ventricular , Humanos , Feminino , Masculino , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/fisiopatologia , Adulto , Pessoa de Meia-Idade , Fibrilação Ventricular/cirurgia , Fibrilação Ventricular/fisiopatologia , Radiocirurgia/tendências , Pesquisas sobre Atenção à Saúde , Técnicas Eletrofisiológicas Cardíacas , Recidiva , Resultado do Tratamento , Padrões de Prática Médica/tendências , Padrões de Prática Médica/estatística & dados numéricos , Cardiologistas/tendências , Eletrofisiologia Cardíaca/tendências
2.
Herzschrittmacherther Elektrophysiol ; 35(1): 83-90, 2024 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-38289503

RESUMO

Cardiovascular implantable electronic devices (CIED) are an important part of modern cardiology and careful perioperative planning of these procedures is necessary. All information relevant to the indication, the procedure, and the education of the patient must be available prior to surgery. This provides the basis for appropriate device selection. Preoperative antibiotic prophylaxis and perioperative anticoagulation management are essential to prevent infection. After surgery, postoperative monitoring, telemetric control, and device-based diagnostics are required before discharge. These processes need to be adapted to the increasing trend towards outpatient care. This review summarises perioperative management based on practical considerations.


Assuntos
Cardiologia , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos
3.
Herzschrittmacherther Elektrophysiol ; 34(4): 339-350, 2023 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-37917360

RESUMO

Lead extraction due to infection or lead dysfunction has become more important in recent years. Patients with high risk of severe and life-threatening complications should only undergo surgery in experienced centers where appropriate personnel and equipment are available. In this review, different techniques and methods to safely and successfully perform transvenous lead extraction are summarized.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Estudos Retrospectivos
4.
Pacing Clin Electrophysiol ; 46(8): 875-881, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37483154

RESUMO

AIM: The implementation of 3D mapping systems plays an important role in interventional electrophysiology (EP) in recent years. The aim of the present study was to evaluate use of 3D mapping systems regarding fluoroscopy and procedure duration. METHOD: In the "Go for Zero Fluoroscopy" project 25 European centers provided data of consecutive EP procedures. Data on use of 3D mapping systems as well as utilization of contact force catheters and multipolar mapping catheters were associated with fluoroscopy time, dose area product (DAP), and procedure duration. RESULT: A 3D mapping system was used in 966 (54%) cases. Use of 3D mapping for atrioventricular nodal reentry tachycardia (AVNRT) was associated with reduced fluoroscopy time (p < 0.001), DAP (p = 0.04) but increased procedure time (p = 0.029). Moreover, fluoroscopy time (p < 0.001) and DAP (p = 0.005) were significantly lower in the 3D mapping group in ablation of typical atrial flutter. However, the procedure time (p < 0.001) increased. Use of 3D mapping in the ablation of accessory pathway (AP) was associated with reduced fluoroscopy time (p < 0.001) and DAP (p < 0.001) with no significant increase in procedure time (p = 0.066). In the case of atrial fibrillation, a 3D mapping system was used in 485 patients (75.8%). Additional use of a contact force catheter was associated with lower fluoroscopy time (p < 0.001) and DAP (p < 0.001). Use of a multipolar mapping catheter was associated with lower fluoroscopy time (p = 0.002). The implementation of 3D mapping systems in the ablation of ventricular tachycardias resulted in a significant increase in the procedure time (p = 0.001) without significant differences regarding the DAP (p = 0.773) and fluoroscopy time (p = 0.249). CONCLUSION: Use of 3D mapping systems in ablation of supraventricular tachycardias is associated with lower radiation exposure. Nevertheless, the procedure time often increases, except in the case of ablation for AP. Use of contact force catheters and multipolar mapping catheters is associated with yet lower radiation exposure values. Prospective randomized studies are needed to further elucidate potential benefit of these technological tools.


Assuntos
Feixe Acessório Atrioventricular , Fibrilação Atrial , Ablação por Cateter , Humanos , Estudos Prospectivos , Resultado do Tratamento , Fibrilação Atrial/cirurgia , Feixe Acessório Atrioventricular/cirurgia , Eletrofisiologia Cardíaca , Fluoroscopia/métodos , Ablação por Cateter/métodos
5.
Herzschrittmacherther Elektrophysiol ; 33(3): 341-350, 2022 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-35986095

RESUMO

In contrast to typical atrial flutter, atypical atrial flutter is a heterogeneous group of right and left atrial macro- or localized reentry tachycardias whose critical component for maintaining tachycardia is not the cavotricuspid isthmus. Atypical atrial flutter occurs more frequently after previous catheter ablation and after cardiac surgery. The intraprocedural success rate during ablation is high, although the recurrence rate depends on structural changes in the atria as well as the underlying mechanism. This article provides an overview of the mechanisms as well as mapping and ablation strategies of the most common forms of right and left atrial atypical atrial flutter. This article is part of the "EP Basics" series for targeted continuing education in invasive electrophysiology. Basics, clinic and therapy of atypical atrial flutter are presented with focus on clinically relevant aspects. Procedures and findings of invasive electrophysiological diagnostics and ablation treatment are the focus of this article.


Assuntos
Fibrilação Atrial , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Humanos , Taquicardia/cirurgia
6.
Front Psychiatry ; 13: 827967, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35782428

RESUMO

Background: Heart failure (HF) is associated with development of depressive symptoms and reduced quality of life (QoL). Patients with HF and an implantable cardioverter-defibrillator (ICD) were evaluated regarding depressive symptoms and QoL. Methods: The present study included 446 patients with HF and an ICD. Depressive symptoms were assessed using the Patient Health Questionnaire 9 (PHQ-9), QoL was evaluated using the Minnesota Living with Heart Failure Questionnaire (MLHFQ). Functional ability and exercise tolerance were assessed at inclusion and after 6 months with help of the 6-min walking test (6MWT). Results: Patients included in the study had a mean age of 65.8 years and were predominantly male (83.6%), with mostly ischemic (n = 277; 62.1%) or dilated (n = 150; 33.6%) cardiomyopathy. One hundred ninety-three (43.2%) patients had depressive symptoms, of whom 75 patients (16.8%) were classified as moderate to severe depression according to the PHQ-9 at baseline. Depressive symptoms were associated with low QoL independent of NYHA functional class. High NYHA functional class, high PHQ-9 score, age and body mass index (BMI) were associated with a lower 6MWT at enrollment, while depressive symptoms (expressed as higher PHQ-9 score) and age were associated with a lower 6MWT after 6 months. Patients with history of smoking and a higher BMI showed higher PHQ-9 scores after 6 months. Patients under antidepressant medication showed improved PHQ-9 score after 6 months, indicating controlled/treated depression. However, patients with low QoL at inclusion remained with low QoL after 6 months. Conclusion: Depressive symptoms correlate with low QoL and lower long-term functional status in patients with HF and an ICD. Depressive symptoms are associated with smoking and obesity, which themselves are risk factors for a poor prognosis in HF. Only a small fraction of patients with HF and ICD showing depressive symptoms receives appropriate treatment. Assessing depressive symptoms and lifestyle factors should be part of a multimodal treatment plan in patients with HF and an ICD.

7.
Herzschrittmacherther Elektrophysiol ; 33(1): 49-54, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34825951

RESUMO

Non-invasive stereotactic radioablation of ventricular tachycardia (VT) substrate has been proposed as a novel treatment modality for patients not eligible for catheter-based ablation or in whom this approach has failed. Initial clinical results are promising with good short-term efficacy in VT suppression and tolerable side effects. This article reviews the current clinical evidence for cardiac radioablation and gives an overview of important preclinical and translational results. Practical guidance is provided, and a cardiac radioablation planning and treatment workflow based on expert consensus and the authors' institutional experience is set out.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Arritmias Cardíacas/cirurgia , Coração , Humanos , Imageamento Tridimensional , Taquicardia Ventricular/terapia , Resultado do Tratamento
8.
Herzschrittmacherther Elektrophysiol ; 32(4): 550-562, 2021 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-34735629

RESUMO

In the current guidelines on treatment of atrial fibrillation, cryoballoon-based catheter ablation of atrial fibrillation is recommended in addition to radiofrequency ablation and has become established as a standard procedure in the clinical routine of many centers for index pulmonary vein isolation. A safe, simplified and often durable pulmonary vein isolation can be achieved by a systematic approach. This review article provides a practical guide for all steps of cryoballoon-based pulmonary vein isolation, including preprocedural preparation and postinterventional follow-up. Both cryoballoon systems currently available on the market are considered.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
9.
Pacing Clin Electrophysiol ; 44(11): 1853-1860, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34564877

RESUMO

AIMS: Atrial fibrillation (AF) catheter ablation is a common procedure requiring in most cases the use of fluoroscopy. We aimed to evaluate the factors associated with a lower dose of fluoroscopy used during AF ablation with cryoballoon or radiofrequency. METHODS: In this prospective European registry, centers were requested to provide procedural characteristics of consecutive AF ablation cases. Lower doses of fluoroscopy were defined as those with dose-area-product (DAP) under the median dose used in the radiofrequency and the cryoballoon ablation groups. RESULTS: A total of 638 AF ablation procedures were collected (n = 492 for radiofrequency and n = 146 for cryoballoon ablation groups) in 25 centers. The median [IQR] DAP were 926 [349;2092] and 1516 [418;3408] cGy*cm2 in the radiofrequency and cryoballoon groups, respectively. Main factors associated with lower DAP in cryoballoon ablation group were electrophysiology dedicated laboratory (OR 6.04, 95%CI 1.16-31.54; P = .03) and frequent dosimetry report (OR 21.39, 95%CI 5.43-98.54; P = .03). Main factors associated with lower DAP in the radiofrequency ablation group were the use of a chest dosimeter (OR 12.57, 95% CI 2.88-54.90; P = .01), biplane X-ray equipment (OR 3.12, 95%CI 1.89-5.16; P < .01), university hospital (OR 2.10, 95%CI 1.35-3.25; P = .01), electrophysiology dedicated laboratory (OR 2.45, 95%CI 1.48-4.05; P < .01) and use of contact force enabled catheter (OR 22.60, 95%CI 6.82-74.88; P < .01). CONCLUSION: This real-life study of fluoroscopy use during AF ablation provides new data about current practices across European countries. Technological advances and quality of the fluoroscopic environment were the main factors associated with lower radiation dose during AF ablation.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Doses de Radiação , Adulto , Idoso , Europa (Continente) , Feminino , Fluoroscopia , Hospitais Universitários , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros
10.
Cardiology ; 146(5): 600-606, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34218228

RESUMO

BACKGROUND: The purpose of this study was to analyze electrophysiologists' radiation-protective devices for occupational exposure across European countries. METHODS: Data reported herein were gathered from the international, multicenter prospective Go for Zero Fluoroscopy registry performed in years 2018-2019. The registry encompassed 25 European electrophysiological centers from 14 countries and up to 5 operators from each center. RESULTS: The analysis included 95 operators (median age: 39 years, 85% of male, median training time: 5 years). The most frequently used X-ray protection tools (used by ≥80% of the group) were lead aprons, thyroid shields, screens below the table, glass in the laboratory, and least often (<7%) protective gloves and cabin. No statistically significant differences regarding the number of procedures performed monthly, electrophysiologists' experience and gender, and radiation exposure dose or radiation protection tools were observed, except lead thyroid shields and eyeglasses, which were more often used in case of fewer electrophysiological procedures performed (<20 procedures per month). Operators who were protected by >4 X-ray protection tools were exposed to lower radiation levels than those who were protected by ≤4 X-ray protection tools (median radiation exposure: 0.6 [0.2-1.1] vs. 0.2 [0.1-0.2] mSv per month, p < 0.0001; 1.1 [0.1-12.0] vs. 0.5 [0.1-1.1] mSv per year, p < 0.0001), respectively. CONCLUSIONS: Electrophysiologists' radiation-protective devices for occupational exposure are similar across European centers and in accordance with the applicable X-ray protection protocols, irrespective of the level of experience, number of monthly performed EP procedures, and gender.


Assuntos
Proteção Radiológica , Adulto , Europa (Continente) , Fluoroscopia/efeitos adversos , Humanos , Masculino , Estudos Prospectivos , Sistema de Registros
11.
Herzschrittmacherther Elektrophysiol ; 32(2): 285-287, 2021 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-33944993

RESUMO

Many young women in cardiology are concerned about radiation exposure, and this issue contributes to the low number of female interventional cardiologists. The proportion of women in interventional electrophysiology is particularly low. However, radiation exposure during catheter ablation of arrhythmias can be minimized and even avoided completely using modern 3D mapping systems. The "zero fluoro" approach can improve patients' safety but also motivate more women to become interventional electrophysiologists.


Assuntos
Cardiologia , Ablação por Cateter , Exposição à Radiação , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Eletrofisiologia Cardíaca , Feminino , Humanos
12.
Europace ; 23(7): 1106-1113, 2021 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-33842972

RESUMO

Novel wearable devices for heart rhythm analysis using either photoplethysmography (PPG) or electrocardiogram (ECG) are in daily clinical practice. This survey aimed to assess impact of these technologies on physicians' clinical decision-making and to define, how data from these devices should be presented and integrated into clinical practice. The online survey included 22 questions, focusing on the diagnosis of atrial fibrillation (AF) based on wearable rhythm device recordings, suitable indications for wearable rhythm devices, data presentation and processing, reimbursement, and future perspectives. A total of 539 respondents {median age 38 [interquartile range (IQR) 34-46] years, 29% female} from 51 countries world-wide completed the survey. Whilst most respondents would diagnose AF (83%), fewer would initiate oral anticoagulation therapy based on a single-lead ECG tracing. Significantly fewer still (27%) would make the diagnosis based on PPG-based tracing. Wearable ECG technology is acceptable for the majority of respondents for screening, diagnostics, monitoring, and follow-up of arrhythmia patients, while respondents were more reluctant to use PPG technology for these indications. Most respondents (74%) would advocate systematic screening for AF using wearable rhythm devices, starting at patients' median age of 60 (IQR 50-65) years. Thirty-six percent of respondents stated that there is no reimbursement for diagnostics involving wearable rhythm devices in their countries. Most respondents (56.4%) believe that costs of wearable rhythm devices should be shared between patients and insurances. Wearable single- or multiple-lead ECG technology is accepted for multiple indications in current clinical practice and triggers AF diagnosis and treatment. The unmet needs that call for action are reimbursement plans and integration of wearable rhythm device data into patient's files and hospital information systems.


Assuntos
Fibrilação Atrial , Dispositivos Eletrônicos Vestíveis , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Tomada de Decisão Clínica , Eletrocardiografia , Feminino , Humanos , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Fotopletismografia
13.
ESC Heart Fail ; 8(2): 1502-1508, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33538124

RESUMO

AIMS: Patients with adult congenital heart disease (ACHD) carry an increased risk for sudden cardiac death. Implantable cardioverter-defibrillator (ICD) therapy may be challenging in these patients due to anatomical barriers, repeated cardiac surgery, or complicated transvenous access. Thus, the subcutaneous ICD (S-ICD) can be a promising alternative in this patient population. Patients with ACHD show significant electrocardiogram (ECG) abnormalities, which could affect S-ICD sensing because it depends on surface ECG. METHODS AND RESULTS: One hundred patients with ACHD were screened for S-ICD eligibility. Standard ECG-based screening test and automated S-ICD screening test were performed in all patients. Sixty-six patients (66%) were male. Underlying congenital heart disease (CHD) was mainly CHD of great complexity (71%) and moderate complexity (29%), including repaired tetralogy of Fallot (20%), which was the most common entity. Thirty-seven patients (37%) already had a pacemaker (23%) or ICD (14%) implanted. Automated screening test identified 83 patients (83%) eligible for S-ICD implantation in either left parasternal position (78%) or right parasternal position (75%). Absence of sinus rhythm, QRS duration, and a paced QRS complex were associated with S-ICD screening failure in univariate analysis. Receiver operating characteristic curve and multivariate analysis revealed a QRS duration ≥148 ms as the only independent predictor for S-ICD screening failure. CONCLUSIONS: Patients with ACHD show satisfactory eligibility rates (83%) for S-ICD implantation utilizing the automated screening test, including patients with CHD of high complexity. S-ICD therapy should be considered with caution in ACHD patients with a QRS duration ≥148 ms and/or need for ventricular pacing.


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Adulto , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Definição da Elegibilidade , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia , Humanos , Masculino , Seleção de Pacientes
14.
Clin Cardiol ; 44(1): 36-42, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33220000

RESUMO

BACKGROUND: Fluoroscopy has been an essential part of every electrophysiological procedure since its inception. However, till now no clear standards regarding acceptable x-ray exposure nor recommendation how to achieve them have been proposed. HYPOTHESIS: Current norms and quality markers required for optimal clinical routine can be identified. METHODS: Centers participating in this Europe-wide multicenter, prospective registry were requested to provide characteristics of the center, operators, technical equipment as well as procedural settings of consecutive cases. RESULTS: Twenty-five centers (72% university clinics, with a mean volume of 526 ± 348 procedures yearly) from 14 European countries provided data on 1788 cases [9% diagnostic procedures (DP), 38% atrial fibrillation (AF) ablations, 44% other supraventricular (SVT) ablations, and 9% ventricular ablations (VT)] conducted by 95 operators (89% male, 41 ± 7 years old). Mean dose area product (DAP) and time was 304 ± 608 cGy*cm2 , 3.6 ± 4.8 minutes, 1937 ± 608 cGy*cm2 , 15.3 ± 15.5 minutes, 805 ± 1442 cGy*cm2 , 10.6 ± 10.7 minutes, and 1277 ± 1931 cGy*cm2 , 10.4 ± 12.3 minutes for DP, AF, SVT, and VT ablations, respectively. Seven percent of all procedures were conducted without any use of fluoroscopy. Procedures in the lower quartile of DAP were performed more frequently by female operators (OR 1.707, 95%CI 1.257-2.318, P = .001), in higher-volume center (OR 1.001 per one additional procedure, 95%CI 1.000-1.001, P = .002), with the use of 3D-mapping system (OR 2.622, 95%CI 2.053-3.347, P < .001) and monoplane x-ray system (OR 2.945, 95%CI 2.149-4.037, P < .001). CONCLUSION: Exposure to ionizing radiation varies widely in daily practice for all procedure. Significant opportunities for harmonization of exposure toward the lower range has been identified.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Fluoroscopia/métodos , Sistema de Registros , Cirurgia Assistida por Computador/métodos , Adulto , Fibrilação Atrial/diagnóstico , Europa (Continente) , Feminino , Humanos , Masculino , Estudos Prospectivos
15.
J Cardiovasc Electrophysiol ; 31(10): 2689-2695, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32648343

RESUMO

INTRODUCTION: Noninvasive ablative radiotherapy of cardiac arrhythmias (stereotactic ablative body radiation) has shown promising initial results. Precise targeting of the arrhythmogenic substrate is paramount to limit adverse effects to healthy myocardium, organs at risk, and cardiac implantable electronic devices. Using electroanatomic maps for treatment planning is technically challenging. METHODS AND RESULTS: Using the free open-source 3D Slicer software platform we established a workflow for high-precision target definition based on electroanatomic maps. An import plug-in for 3D Slicer has been designed that reads electroanatomic maps generated with three mapping systems in widespread clinical use. Using our proposed workflow in a real-world patient case we were able to align the map to the computed tomography (CT) with a mean distance of 3.1 mm. Thus, points defined on the map were translated into CT space with high accuracy and a radiotherapy treatment volume was defined in CT space based on these map-derived points. CONCLUSION: We describe a novel high-precision target definition method for stereotactic ablation of cardiac arrhythmias. Multimodal integration of the electroanatomic map with the planning CT allows for highly accurate localization of previously identified electrophysiological features in CT space. It remains to be shown whether this novel planning workflow leads to superior ablation outcomes when compared with other approaches.


Assuntos
Ablação por Cateter , Coração , Humanos , Software , Tomografia Computadorizada por Raios X , Fluxo de Trabalho
16.
PLoS One ; 8(11): e80454, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24260393

RESUMO

BACKGROUND: Myostatin is a muscle derived factor that functions as a negative regulator of skeletal muscle growth. Induction of myostatin expression was observed in rodent models of muscle wasting and in cachectic patients with cancer or pulmonary disease. Therefore, there is an increasing interest to use serum myostatin as a biomarker. METHODS: We established an immunoradiometric sandwich assay (IRMA), which uses a commercially available chicken polyclonal, affinity purified antibody directed against human myostatin prodomain. We determined the serum concentrations of myostatin prodomain in 249 healthy individuals as well as 169 patients with heart failure, 53 patients with cancer and 44 patients with chronic pulmonary disease. RESULTS: The IRMA had a detection limit of 0.7ng/ml, an intraassay imprecision of ≤14.1% and an interassay imprecision of ≤ 18.9%. The specificity of our assay was demonstrated by size exclusion chromatography, detection of myostatin by Western-blotting and a SMAD-dependent transcriptional-reporter assay in the signal-rich serum fractions, as well as lack of interference by unspecific substances like albumin, hemoglobin or lipids. Myostatin prodomain was stable at room temperature and resistant to freeze-thaw cycles. Apparently healthy individuals over the age of 55 had a median myostatin prodomain serum concentration of 3.9ng/ml (25(th)-75(th) percentiles, 2-7ng/ml) and we could not detect increased levels in patients with stable chronic heart failure or cancer related weight loss. In contrast, we found strongly elevated concentrations of myostatin prodomain (median 26.9ng/ml, 25(th)-75(th) percentiles, 7-100ng/ml) in the serum of underweight patients with chronic pulmonary disease. CONCLUSIONS: We established a highly specific IRMA for the quantification of myostatin prodomain concentration in human serum. Our assay could be useful to study myostatin as a biomarker for example in patients with chronic pulmonary disease, as we detected highly elevated myostatin prodomain serum levels in underweight individuals of this group.


Assuntos
Ensaio Imunorradiométrico/métodos , Miostatina/sangue , Adulto , Idoso , Biomarcadores/sangue , Biomarcadores/metabolismo , Doença Crônica , Feminino , Neoplasias Gastrointestinais/sangue , Neoplasias Gastrointestinais/metabolismo , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/metabolismo , Humanos , Ensaio Imunorradiométrico/normas , Pneumopatias/sangue , Pneumopatias/metabolismo , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/metabolismo , Músculo Esquelético/fisiologia , Atrofia Muscular/sangue , Atrofia Muscular/etiologia , Atrofia Muscular/metabolismo , Miostatina/metabolismo , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
J Cardiovasc Pharmacol Ther ; 18(2): 109-12, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22837540

RESUMO

Dronedarone is a new antiarrhythmic drug for patients with nonpermanent atrial fibrillation (AF). A relatively consistent finding in all trials studying dronedarone was a moderate but significant elevation of serum creatinine. Since dronedarone competes for the same organic cation transporter in the distal renal tubule with creatinine, serum creatinine and its derived estimated glomerular filtration rate might not reflect true renal function in patients on dronedarone. We therefore investigated alternative markers for renal function in these patients. We prospectively included 20 patients with nonpermanent AF in whom dronedarone 400 mg twice daily was started. Patients had normal renal function and serum creatinine; serum cystatin C and creatinine clearance were measured before treatment and 10 and 90 days after treatment started. Mean serum creatinine level for all 20 patients at baseline (day 0) was 84.55 ± 12.14 and 87.8 ± 17.59 µmol/L on day 10. This slight increase in all patients was not significant. Patients were now divided into the predefined groups of "increased creatinine" (increase in serum creatinine level > 1 standard deviation) and "not increased creatinine." Patients with increased creatinine levels (n = 5) showed a significant elevation of serum creatinine levels from day 0 to day 10 (82.4 ± 9.18 to 104.4 ± 12.74 µmol/L; P = .003), whereas change in serum creatinine levels in the not increased creatinine group (n = 15) was not significant. Serum cystatin C levels remained stable in both of these groups (increased creatinine group: 0.76 ± 0.08 to 0.78 ± 0.08 mg/L; P = .65; not increased creatinine group: 0.77 ± 0.108 to 0.77 ± 0.107 mg/L; P = .906). In conclusion, cystatin C represents an easily available and reliable biomarker for estimation of true renal function in patients on dronedarone treatment.


Assuntos
Amiodarona/análogos & derivados , Antiarrítmicos/uso terapêutico , Creatinina/sangue , Cistatina C/sangue , Rim/efeitos dos fármacos , Rim/fisiologia , Adulto , Idoso , Amiodarona/farmacologia , Amiodarona/uso terapêutico , Antiarrítmicos/farmacologia , Fibrilação Atrial/sangue , Fibrilação Atrial/tratamento farmacológico , Biomarcadores/sangue , Dronedarona , Feminino , Humanos , Testes de Função Renal/métodos , Masculino , Pessoa de Meia-Idade , Estabilidade Proteica , Reprodutibilidade dos Testes , Regulação para Cima/fisiologia
19.
J Interv Card Electrophysiol ; 29(1): 57-62, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20556498

RESUMO

PURPOSE: Modulation of the intrinsic cardiac autonomic nervous system (ICANS) has been described to occur during radiofrequency pulmonary vein (PV) isolation for paroxysmal atrial fibrillation (AF) and has been controversially proposed to increase clinical success. Energy source used for PV isolation might influence ICANS modulation. The effect of balloon-delivered cryoenergy on the ICANS is unknown. We conducted a study investigating acute periprocedural effect on ICAN as well as changes in heart rate variability (HRV) for standard deviation of normal-to-normal intervals (SDNN) and triangular index (TI) as surrogates for ICANS modulation after cryoballoon PV isolation. METHODS: Fourteen consecutive patients without structural heart disease underwent cryoballoon PV isolation for paroxysmal atrial fibrillation. Acute changes in heart rate requiring pacing during the procedure were recorded. HRV was tested by Holter ECG for SDNN and TI before ablation and after 1 week, 1 month, and 3 months following ablation. RESULTS: Fifty-five out of 56 PV were isolated (98%) with short-term 6-month freedom from paroxysmal AF of 64% by one single procedure. Five patients (36%) showed significant bradycardia during balloon thawing requiring temporary pacing. HRV decreased significantly immediately after PV isolation for both SDNN and TI until 1 month, gradually normalizing toward 3 months follow-up. HRV modulation was not different between patients with or without AF recurrences. CONCLUSIONS: Cryoballoon PV isolation significantly modulates the ICANS, but only temporarily for up to 3 months, measured by HRV changes after ablation.


Assuntos
Fibrilação Atrial/cirurgia , Sistema Nervoso Autônomo , Ablação por Cateter/métodos , Criocirurgia/métodos , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Estudos de Coortes , Eletrocardiografia , Eletrocardiografia Ambulatorial , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica/fisiologia , Cuidados Pós-Operatórios/métodos , Medição de Risco , Índice de Gravidade de Doença , Taquicardia Paroxística/diagnóstico , Taquicardia Paroxística/cirurgia , Resultado do Tratamento
20.
Acta Neurochir Suppl ; 102: 93-7, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19388296

RESUMO

BACKGROUND: Usually, decompressive craniectomy (DC) in patients with increased intracranial pressure (ICP) is combined with resection of the dura and large-scale duroplasty. However, duroplasty is cumbersome, lengthens operation time and requires heterologous or autologous material. In addition, the swelling brain could herniate into the duroplasty with kinking of the superficial veins at the sharp cutting edges and subsequent ICP exacerbation. Several longitudinal durotomies avoid these limitations, but it remains a matter of discussion if durotomies reduce ICP sufficiently. METHODS: DC was performed in ten patients (mean age 45 years) with increased ICP after head trauma or subarachnoid hemorrhage. After craniectomy, the dura was opened by three to four durotomies from midline to the temporal base. Duration of surgical procedure and ICP during each surgical step and postoperatively were recorded. FINDINGS: Mean duration of surgery was 90 +/- 10 min. ICP prior to skin incision was 39 +/- 12 mmHg and dropped to 22 +/- 9 mmHg after craniectomy. During durotomy ICP decreased stepwise and reached stable values of 12 +/- 6 mmHg at the end of surgery. On days 1-10 after surgery, ICP values ranged between 12-17 mmHg. CONCLUSION: This study showed that durotomy is a fast and easy, but likewise effective method to lower ICP further after craniectomy.


Assuntos
Craniotomia/métodos , Descompressão Cirúrgica/métodos , Dura-Máter/cirurgia , Hipertensão Intracraniana/cirurgia , Pressão Intracraniana/fisiologia , Adulto , Encefalopatias/complicações , Encefalopatias/cirurgia , Feminino , Escala de Resultado de Glasgow , Humanos , Hipertensão Intracraniana/etiologia , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Fatores de Tempo , Resultado do Tratamento